Side and Rear Setback Calculator

Setback for a wall height, or the wall height allowed at a setback

Enter a wall height to find the setback it needs, or a setback to find the highest wall allowed. Results are not rounded up. Heights are measured from natural ground level.

Side and rear setback

Clause 54 A2-3 · Clause 55 B17 · Building Regulations reg 79

Neighbour’s north-facing window

Clause 54 A4-2 · Clause 55 B20 · Building Regulations reg 82

Thinking about a separate small second dwelling at the back, a granny flat? See the Granny Flat Planning & Feasibility Report.

Which rules apply

SituationRules that generally apply
One dwelling or a small second dwelling on a lot under 300 m² in a residential zone, planning permit neededClause 54 (A2-3 for side and rear setbacks, A4-2 for north-facing windows), assessed as part of the planning permit.
Lot over 300 m², no planning permit neededBuilding Regulations 2018 Part 5 (reg 79 and reg 82), subject to Schedule 6 to the Building Regulations. From 27 October 2026 reg 79 applies Clause 54 Standard A2-3 directly. Council report and consent is the route if a regulation is not met.
Two or more dwellings on a lotClause 55 (B17 and B20), assessed as part of the planning permit.

Overlays, local schedules and the zone can change which rules apply. Check the property on VicPlan, or ask a building designer or building surveyor.

How the rules work
  • Wall height up to 3.6 m: setback is 1 m.
  • Wall height from 3.6 m to 6.9 m: 1 m plus 0.3 m for each metre over 3.6 m (0.6 m for a neighbour’s north-facing window).
  • Wall height over 6.9 m: add a further 1 m for each metre over 6.9 m.
  • A wall at 6.9 m high needs a setback of 1.99 m, or 2.98 m for a north-facing window.
  • Sunblinds, verandahs, eaves, gutters and similar parts can project up to 0.5 m into the setback (Clause 54 A2-3).
  • The north-facing window rule applies where the neighbour’s habitable room window faces within 20 degrees west to 30 degrees east of north and is within 3 m of the boundary. The setback applies for at least 3 m either side of the window (Clause 54 A4-2).
  • Walls on or within 200 mm of a boundary follow separate rules for length and height.

Sources: Department of Transport and Planning, one dwelling on a lot guide and one dwelling and small second dwelling guidelines (September 2025). Clause 54 figures checked on 26 October 2026. Building Regulations 2018 Part 5 as amended from 27 October 2026 by the Building Amendment (Siting and Other Matters) Regulations 2026 (S.R. No. 173/2026), read on 29 October 2026. This tool is general information only. It is not legal, planning or building surveying advice. Planning schemes and building regulations change, so confirm the current requirements with your council or building surveyor before you rely on a result.